Experimental geometry
Experimental geometry¶
A spectrum — RBS or PIXE — depends on three directions: the beam, the detector and the sample normal. Three angles between them describe the experiment, each set on the data buffer for the RBS detector (and in the PIXE prompt for the PIXE detector):
| Command | Angle between | What it sets |
|---|---|---|
THETA |
the beam (looking back at the source) and the sample normal | the beam's path into the sample |
PHI |
the beam (looking back at the source) and the detector: 180° minus the scattering angle | the kinematics and the cross section |
PSI |
the detector and the sample normal | the particles' path out of the sample |
A detector at a scattering angle of 170° is PHI 10, not PHI 170 — RUMP's
convention, kept by pyRUMP (see Things that will catch you
out).
The three angles are not independent: they are the angles between three
directions, so PSI can only lie between |THETA − PHI| and THETA + PHI.
GEOMETRY says how pyRUMP gets PSI, and there are
three cases:
GEOMETRY |
Where the detector is | PSI |
|---|---|---|
IBM |
beside the beam, in the plane the sample normal turns in | computed: PSI = |THETA + PHI| |
CORNELL |
above or below the beam, in the plane of the tilt axis | computed: cos PSI = cos THETA × cos PHI |
GENERAL |
anywhere | typed in |
With IBM or CORNELL, a typed PSI is ignored.
The figures below show all three in the same chamber, at the same angles
(THETA 25, PHI 35), and with the same colours: the beam in black, the
detector in purple, the sample normal in blue; THETA in red, PHI in
orange, PSI in purple. In each, the beam comes in horizontally and the
sample turns about a vertical tilt axis, like a door: only the detector
moves from one case to the next.
IBM geometry¶
The detector sits beside the beam, in the horizontal plane (red) in which the sample normal turns. The tilt axis is then perpendicular to the scattering plane — the plane of the beam and the detector — and the beam, the detector and the normal never leave the red plane. Looking down the tilt axis, every angle is drawn true size. The figure shows the two ways the sample can turn, each with its 3D view (a, b), its top view (c, d) and its RUMP commands (e, f):

PSI = |THETA + PHI|. The sign of THETA says which way the sample turns:
positive away from the detector, negative towards it. RUMP's own manual:
"The sign ambiguity is resolved so that PSI = THETA+PHI. If the sample normal
points to the detector, then THETA should equal −PHI."
examples/MnPt.RBS has GEOMETRY GENERAL, THETA -9, PHI 11, PSI 20.
Its PSI 20 = 9 + 11 is the IBM value for a sample turned 9° away from the
detector, which RUMP's IBM convention would write as THETA 9. The
acquisition software writes THETA -9 and spells PSI out, so the file
needs GENERAL.
Cornell geometry¶
The detector sits below the beam, so the tilt axis lies in the scattering plane, across the beam. In the figure both are vertical: the beam comes in horizontally, the detector looks back and down, and the sample turns about the vertical axis like a door. Its normal therefore swings out of the scattering plane, and the three angles lie in different planes:
THETAin the plane of the beam and the normal (red, horizontal here);PHIin the plane of the beam and the detector, the scattering plane (orange, vertical);PSIacross the two, between the normal and the detector.
No single flat drawing shows all three at their true size. The overview (a)
shows them together; the top view (b), looking down the tilt axis onto the
red plane, shows THETA true; the front view (c), looking onto the orange
plane, shows PHI true:

cos PSI = cos THETA × cos PHI. The sign of THETA only says which way the
sample turns, so THETA -25 gives the same PSI as THETA 25. PSI
always lies between the two IBM values for the same THETA and PHI —
here 42.1°, between 10° and 60°.
General geometry¶
With GENERAL, pyRUMP uses PSI as typed: it is for a normal that neither
rule describes — a sample tilted about two axes, or a detector out of both
the IBM and the CORNELL positions. In the figure the normal is still
THETA 25° from the beam, but it rises 15° out of the red plane where
CORNELL keeps it. Its dashed projection onto the red plane shows how far the
sample has swung (20.2°, true size in the top view b); the dotted line, how
far it rises. PSI comes out at 53.6° — between CORNELL's 42.1° and IBM's
60° — and only a typed PSI can say so:

Acquisition files often use GENERAL and spell all three angles out:
examples/MnPt.RBS has GEOMETRY GENERAL, THETA -9, PHI 11, PSI 20
(see IBM geometry for what its PSI means).
Fitting the tilt¶
When fitting, PERT THETA varies THETA; with IBM or
CORNELL the exit angle follows it, with GENERAL it stays at PSI. The
PIXE detector's tilt follows only with PAIR ON or THETA RBS (below).
The PIXE detector¶
The PIXE detector is placed the same way, in the same three cases: in the
figures above, "detector" can be either. Its GEOMETRY, THETA, PHI and
PSI are typed in the PIXE prompt, apart from
the RBS buffer's, since the two detectors stand in different places. The
default is GEOMETRY IBM, PHI 45 and THETA 0: the detector beside the
beam, 45° from it, and the beam at normal incidence, so the X-rays leave at
45° to the normal.
The sample is one, tilted once for both detectors: THETA RBS in the PIXE
prompt takes the tilt from the RBS buffer, and follows it through a
PERT THETA fit. PAIR ON — the .RBS and .PIX files of one run read
together — always does, and refuses a THETA of the PIXE prompt's own. The PIXE detector's own GEOMETRY then says what the
tilt does to its X-rays. On the RC43 endstation, the RBS file's THETA -9
turns the sample towards the PIXE detector, beside the beam: IBM,
|−9 + 45| = 36°.