Skip to content

Experimental geometry

Experimental geometry

A spectrum — RBS or PIXE — depends on three directions: the beam, the detector and the sample normal. Three angles between them describe the experiment, each set on the data buffer for the RBS detector (and in the PIXE prompt for the PIXE detector):

Command Angle between What it sets
THETA the beam (looking back at the source) and the sample normal the beam's path into the sample
PHI the beam (looking back at the source) and the detector: 180° minus the scattering angle the kinematics and the cross section
PSI the detector and the sample normal the particles' path out of the sample

A detector at a scattering angle of 170° is PHI 10, not PHI 170 — RUMP's convention, kept by pyRUMP (see Things that will catch you out).

The three angles are not independent: they are the angles between three directions, so PSI can only lie between |THETA − PHI| and THETA + PHI. GEOMETRY says how pyRUMP gets PSI, and there are three cases:

GEOMETRY Where the detector is PSI
IBM beside the beam, in the plane the sample normal turns in computed: PSI = |THETA + PHI|
CORNELL above or below the beam, in the plane of the tilt axis computed: cos PSI = cos THETA × cos PHI
GENERAL anywhere typed in

With IBM or CORNELL, a typed PSI is ignored.

The figures below show all three in the same chamber, at the same angles (THETA 25, PHI 35), and with the same colours: the beam in black, the detector in purple, the sample normal in blue; THETA in red, PHI in orange, PSI in purple. In each, the beam comes in horizontally and the sample turns about a vertical tilt axis, like a door: only the detector moves from one case to the next.

IBM geometry

The detector sits beside the beam, in the horizontal plane (red) in which the sample normal turns. The tilt axis is then perpendicular to the scattering plane — the plane of the beam and the detector — and the beam, the detector and the normal never leave the red plane. Looking down the tilt axis, every angle is drawn true size. The figure shows the two ways the sample can turn, each with its 3D view (a, b), its top view (c, d) and its RUMP commands (e, f):

GEOMETRY IBM at PHI 35, the sample turning about a vertical tilt axis with the detector beside the beam: (a) THETA +25, turned away from the detector, PSI = 60 degrees; (b) THETA -25, turned towards it, PSI = 10 degrees; (c, d) their top views, every angle true size; (e, f) their RUMP commands

PSI = |THETA + PHI|. The sign of THETA says which way the sample turns: positive away from the detector, negative towards it. RUMP's own manual: "The sign ambiguity is resolved so that PSI = THETA+PHI. If the sample normal points to the detector, then THETA should equal −PHI."

examples/MnPt.RBS has GEOMETRY GENERAL, THETA -9, PHI 11, PSI 20. Its PSI 20 = 9 + 11 is the IBM value for a sample turned 9° away from the detector, which RUMP's IBM convention would write as THETA 9. The acquisition software writes THETA -9 and spells PSI out, so the file needs GENERAL.

Cornell geometry

The detector sits below the beam, so the tilt axis lies in the scattering plane, across the beam. In the figure both are vertical: the beam comes in horizontally, the detector looks back and down, and the sample turns about the vertical axis like a door. Its normal therefore swings out of the scattering plane, and the three angles lie in different planes:

  • THETA in the plane of the beam and the normal (red, horizontal here);
  • PHI in the plane of the beam and the detector, the scattering plane (orange, vertical);
  • PSI across the two, between the normal and the detector.

No single flat drawing shows all three at their true size. The overview (a) shows them together; the top view (b), looking down the tilt axis onto the red plane, shows THETA true; the front view (c), looking onto the orange plane, shows PHI true:

GEOMETRY CORNELL at THETA 25, PHI 35, the sample turning about a vertical tilt axis: (a) a 3D overview with the beam-normal plane in red, the beam-detector plane in orange and PSI = 42.1 degrees; (b) the top view, THETA 25 degrees true size; (c) the front view, PHI 35 degrees true size; and the RUMP commands

cos PSI = cos THETA × cos PHI. The sign of THETA only says which way the sample turns, so THETA -25 gives the same PSI as THETA 25. PSI always lies between the two IBM values for the same THETA and PHI — here 42.1°, between 10° and 60°.

General geometry

With GENERAL, pyRUMP uses PSI as typed: it is for a normal that neither rule describes — a sample tilted about two axes, or a detector out of both the IBM and the CORNELL positions. In the figure the normal is still THETA 25° from the beam, but it rises 15° out of the red plane where CORNELL keeps it. Its dashed projection onto the red plane shows how far the sample has swung (20.2°, true size in the top view b); the dotted line, how far it rises. PSI comes out at 53.6° — between CORNELL's 42.1° and IBM's 60° — and only a typed PSI can say so:

GEOMETRY GENERAL at THETA 25, PHI 35, with the normal rising 15 degrees out of the horizontal red plane: (a) a 3D overview, PSI = 53.6 degrees; (b) the top view, the 20.2-degree swing true size; (c) the front view, PHI 35 degrees true size; and the RUMP commands with PSI typed in

Acquisition files often use GENERAL and spell all three angles out: examples/MnPt.RBS has GEOMETRY GENERAL, THETA -9, PHI 11, PSI 20 (see IBM geometry for what its PSI means).

Fitting the tilt

When fitting, PERT THETA varies THETA; with IBM or CORNELL the exit angle follows it, with GENERAL it stays at PSI. The PIXE detector's tilt follows only with PAIR ON or THETA RBS (below).

The PIXE detector

The PIXE detector is placed the same way, in the same three cases: in the figures above, "detector" can be either. Its GEOMETRY, THETA, PHI and PSI are typed in the PIXE prompt, apart from the RBS buffer's, since the two detectors stand in different places. The default is GEOMETRY IBM, PHI 45 and THETA 0: the detector beside the beam, 45° from it, and the beam at normal incidence, so the X-rays leave at 45° to the normal.

The sample is one, tilted once for both detectors: THETA RBS in the PIXE prompt takes the tilt from the RBS buffer, and follows it through a PERT THETA fit. PAIR ON — the .RBS and .PIX files of one run read together — always does, and refuses a THETA of the PIXE prompt's own. The PIXE detector's own GEOMETRY then says what the tilt does to its X-rays. On the RC43 endstation, the RBS file's THETA -9 turns the sample towards the PIXE detector, beside the beam: IBM, |−9 + 45| = 36°.