PERT — fitting

PERT — fitting

PERT fits the SIM sample to the active data buffer by least squares. You choose which parameters may vary and which channels count, then run GO. Fitted values are written back into the sample, so SIM SHOW and SIM SAVE show them.

PERT opens its own PERT Command: prompt. A command PERT does not recognise is passed to the RUMP level, which also takes you back there. From the RUMP level, PERT <command> runs a single PERT command without entering the prompt:

Your wish? pert get MnPt.pert go      /* load a saved setup and fit */
Your wish? pert
PERT Command: window 800 1200         /* fit these channels only        */
PERT Command: thickness 2             /* vary layer 2's thickness       */
PERT Command: composition 2 Mn        /* and its Mn content             */
PERT Command: go

Two differences from the original: the data may be in any buffer, not just buffer 1, and MULTI is the default.

Getting around

HELP / ?

usage: HELP [<name>]

Lists the PERT commands. HELP <name> describes one command, with its usage; a name PERT does not know is looked up at the RUMP level.

PERT Command: help thickness

RETURN / QUIT / Q

Goes back to the RUMP level. Inside PERT, QUIT does not exit pyRUMP.

PARMS

Shows the current setup: fit mode, windows, and what is varying.

PERT Command: parms
  mode        multiple variable
  autocmp     off
  autosnap    off
  error win   [1] 800-1200
  norm win    (none)
  varying:
    [1] kev(0)
    [2] layer 2 thickness
    [3] layer 2 composition Mn
    [4] fwhm  bounds 18-25

SHOW

Lists the sample, the same as SIM SHOW. Useful to check layer numbers before selecting parameters.

PERT Command: show

Running a fit

GO

Runs the fit and prints the result (see Reading the fit report). Needs a sample, a data buffer, and at least one varying parameter. Refuses to run if a varying parameter does not match the current MODE (switching MODE normally drops those).

PERT Command: go

SINGLE / MULTI

MULTI (the default) fits all varying parameters together. SINGLE fits them one at a time, in the order they were selected.

PERT Command: single
  single-variable mode

VOLUME

usage: VOLUME [off]

Prints a line for every simulation GO runs, so a long fit visibly makes progress. Off by default.

PERT Command: volume
  messages on

AUTOCMP [new]

usage: AUTOCMP [off]

Runs COMPARE at the end of every GO. Off by default; GET and CLEAR keep the setting.

PERT Command: autocmp
  autocmp on

AUTOSNAP [new]

usage: AUTOSNAP [off]

After every GO, takes a SNAPSHOT of the fit, writing the same files SNAP does, named after the sample: the first word of the data buffer's IDENTIFIER, or its file name. If another dataset already has that name, the data file's own name is used instead, with a warning (see SNAPSHOT). Off by default; GET and CLEAR keep the setting.

  • <sample>.report — the fit result, appended, so refits keep a history
  • <sample>.pert — the PERT setup, as SAVE writes it
  • <sample>.lcm — the fitted sample, as SIM SAVE writes it
  • <sample>_rbs.png — the COMPARE plot, as FIGSAVE writes it (with <sample>_pixe.png when it saves the PIXE window too)
  • <sample>_fit.xeq — the restore macro: pyrump <sample>_fit.xeq is this session again, with the fitted spectrum parameters too (CORRECTION, calibration …)

Tuning by hand after the fit isn't covered: type SNAP again to save it. Its report block is marked set by hand.

PERT Command: autosnap
  autosnap on

REPORT, its old name, still works, so older macros and ~/.pyrumprc files keep working, but it is no longer listed by HELP.

HIGHLIGHT [new]

usage: HIGHLIGHT [off]

Shades the fit's windows on the plots, so it's plain which channels GO fits. In the RBS window, the WINDOW channels are light blue and the NORMALIZE window light orange. In the PIXE window, the PIXWIN channels are light blue. It works in PLOT and COMPARE alike, in both panels of a comparison, and on the channel or the energy axis. Adding or clearing a window redraws the plot at once. On by default; HIGHLIGHT OFF gives clean plots for figures. GET and CLEAR keep the setting, and SAVE doesn't write it. A snapshot keeps it off if you turned it off.

PERT Command: highlight off
  highlight off

COMPARE / CMP

Plots the active buffer against the simulation, with residuals, the same as COMPARE at the RUMP level.

PERT Command: cmp

EXPORTCMP / EC writes the same comparison to a column file from here too, without leaving PERT, and EXPORT writes the active buffer on its own.

Saving and clearing

GET

usage: GET <file> [GO]

Replays a saved .pert setup, replacing the current one. A trailing GO runs the fit right after. .pert is added when the name has no extension.

PERT Command: get MnPt go

SAVE

usage: SAVE <file>

Writes the current setup (windows, fit mode, varying parameters and their bounds) to a .pert file, as the PERT commands that recreate it.

PERT Command: save usual
wrote usual.pert

CLEAR [new]

usage: CLEAR [<n>]

Forgets the whole setup, or only varying parameter n, numbered as PARMS lists them.

PERT Command: clear 3                 /* stop varying parameter [3] */

Windows

WINDOW

usage: WINDOW <first> <last>
usage: WINDOW CLEAR [<n>]

Adds an error window: only these channels count in the fit. Up to 10 windows; with none, the whole spectrum counts. The plots shade them in light blue (HIGHLIGHT). WINDOW CLEAR removes all windows, WINDOW CLEAR <n> only window n. With no argument, shows the setup like PARMS.

PERT Command: window 800 1200
  error windows [1] 800-1200

NORMALIZE

usage: NORMALIZE <first> <last>
usage: NORMALIZE CLEAR

Scales the data to the simulation over these channels, to absorb a charge or dose error. After GO, the scale is stored in the buffer's CORRECTION. Cannot be combined with varying CORRECTION. The plots shade it in light orange (HIGHLIGHT).

PERT Command: normalize 300 400
  normalisation window 300-400

The scale stands for the dose, so with PIXWIN windows it is applied to the PIXE spectrum too.

PIXWIN [new]

usage: PIXWIN <first> <last>
usage: PIXWIN CLEAR [<n>]

Sets the PIXE channels that the parameters fitted to the PIXE spectrum are fitted over. Channels are numbered as the .PIX file numbers them, as PIXE REGION takes them. This is for alloys whose elements overlap in RBS but not in their X-ray lines: Ta–W, Fe–Ni, Ni–Co.

You choose, element by element, which spectrum fits it. COMPOSITION, ATOMS and SPECIES take PIXE after the element (COMPOSITION 2 Fe PIXE). Without it, or with RBS, the element is fitted to the RBS spectrum, as in RUMP. Everything else — thicknesses, calibration, beam — is always fitted to RBS. GO then alternates:

  1. the PIXE parameters, and H with PIXH, fitted to the PIXE spectrum over the PIXWIN channels, everything else held;
  2. the rest fitted to the RBS spectrum over the WINDOW channels, the PIXE parameters held;

and repeats both until no value moves by more than 0.1 % (at most 10 rounds), since the two depend on each other a little: the PIXE yields on the thicknesses, the RBS spectrum on the composition. Each parameter is fitted to one spectrum only, so the two never pull against each other. GO reports each spectrum's chi-square, and how many rounds it took.

  • Put the windows on clear peaks. The PIXE continuum isn't simulated, so a window over background would be fitted to nothing. One window may span a whole group of lines. Overlaps such as Fe Kβ on Ni Kα, or Ta Lβ near W Lα, are fine, because the simulation has every line.
  • Leave an element unvaried as the reference. In MODE COMP only the ratios count: fit Ta to PIXE against a fixed W, and the thickness to RBS. GO refuses every element of a layer fitted to PIXE in MODE COMP.
  • A normalisation window (NORMALIZE) sets the dose for the PIXE data too.

GO refuses PIXE parameters without PIXWIN windows or without a PIXE spectrum in the buffer (PIXE GET, or PAIR ON), and an element with no simulated counts in the windows — O in an oxide, say — since the PIXE spectrum can say nothing about it.

Up to 10 windows. PIXWIN CLEAR removes all of them, PIXWIN CLEAR <n> only window n, and PIXWIN alone lists them. They're saved with SAVE, so snapshots keep them too. The PIXE window shades them (HIGHLIGHT), and its COMPARE scores the chi-square over them. PARMS shows the spectrum each parameter is fitted to, and H:

PERT Command: window 380 500
PERT Command: pixwin 786 994        /* Ta L and W L lines, 7.9-10 keV */
PERT Command: composition 1 Ta pixe
PERT Command: thickness 1
PERT Command: pixh
PERT Command: parms
  mode        multiple variable
  autocmp     off
  autosnap    off
  highlight   on
  error win   [1] 380-500
  norm win    (none)
  PIXE win    [1] 786-994
  PIXE H      K 1   L 1.25   M 1   L fitted (Ta L lines in the PIXE windows)
  varying:
    [1] layer 1 composition Ta       PIXE
    [2] layer 1 thickness            RBS
    [3] PIXH                         PIXE
PERT Command: go
  Fitting film: Si [20000/cm2] - WTa2 [1000/cm2]
  PIXE, channels 786-994: layer 1 composition Ta, PIXH L
  RBS, channels 380-500:  layer 1 thickness

  fit took 0.33 s, 2 rounds PIXE -> RBS

  PIXE: reduced chi-square 1.1153 on 207 dof   (was 10.7757)
  RBS:  reduced chi-square 1.5234 on 120 dof   (was 1.5276)
  40 evaluations, converged
  layer 1 composition Ta            1.01684  +/- 0.02061   (was 2)
  layer 1 thickness               1000 /cm2  +/- 0.2016 /cm2   (was 1000 /cm2)
  PIXH L                           0.990994  +/- 0.008716   (was 1.25)

  film: Si [20000/cm2] - WTa1.02 [1000/cm2]

That is a simulated W–Ta film (truth: Ta 1, H 1) started at Ta 2 with H_L 25% off. From RBS alone the same fit gives Ta to ±0.057; the PIXE lines narrow it to ±0.021. The whole analysis of a measured Fe–Ni film, from loading the data to saving the session, is the FeNi worked example.

PIXWIN and PIXH need all four letters, so that PIXE (or PIX) still opens the PIXE prompt from PERT, as it does at every other prompt.

Parameters

Each command below adds one parameter to vary; selecting the same one again replaces it. Layer numbers are the ones SHOW lists.

Every parameter takes an optional <min> <max> bound at the end: give both or neither. The fit stays inside the bound. PARMS shows it, and SAVE/GET keep it. A THICKNESS bound is in the layer's own unit (the one SHOW lists, usually Å); an ATOMS bound is in 10¹⁵ at/cm².

THICKNESS

usage: THICKNESS <layer> [<min> <max>]

Varies a layer's thickness. Needs MODE COMP. The bound is in the layer's own unit, e.g. Å for a layer SHOW lists in A.

PERT Command: thickness 2 300 360

COMPOSITION

usage: COMPOSITION <layer> <element> [PIXE|RBS] [<min> <max>]

Varies one element's stoichiometry in a layer. The element must already be in that layer. Needs MODE COMP. PIXE fits it to the PIXE spectrum over the PIXWIN channels instead of the RBS one.

PERT Command: composition 2 Mn 2 4

Always keep one element fixed

Only the ratios within a layer matter, so varying every element of a layer together has no effect on the spectrum and the fit fails. In an N-element layer, vary at most N−1 of them.

ATOMS [new]

usage: ATOMS <layer> <element> [PIXE|RBS] [<min> <max>]

Varies one element's own areal density in a layer, keeping the other elements' amounts fixed, in 10¹⁵ at/cm². Needs MODE ATOMS. PIXE fits it to the PIXE spectrum over the PIXWIN channels. With H calibrated and held (no PIXH), every element of a layer can be fitted to PIXE this way, each amount absolute.

PERT Command: atoms 2 Mn

SPECIES

usage: SPECIES <layer> <element> [PIXE|RBS] [<min> <max>]

Varies one element of a layer's SPECIES. The element must already be declared there. PIXE fits it to the PIXE spectrum.

PERT Command: species 2 Au

EQUATION

usage: EQUATION <layer> <n> [<min> <max>]

Varies parameter n of a layer's EQUATION.

PERT Command: equation 2 2            /* the second equation parameter */

STRAGGLE

usage: STRAGGLE [<min> <max>]

Varies the sample's straggling factor.

PERT Command: straggle 0.5 2

FUZZ

Not implemented; it prints an error.

MEV

usage: MEV [<min> <max>]

Varies the beam energy, in MeV.

PERT Command: mev

FWHM

usage: FWHM [<min> <max>]

Varies the detector resolution, in keV.

PERT Command: fwhm 18 25

THETA

usage: THETA [<min> <max>]

Varies the sample tilt, in degrees. With GEOMETRY IBM or CORNELL the exit angle follows it; with GENERAL it stays at PSI (see Experimental geometry).

PERT Command: theta -12 -6

CORRECTION

usage: CORRECTION [<min> <max>]

Varies the buffer's normalisation factor (CORRECTION). Cannot be combined with a NORMALIZE window.

PERT Command: correction

SLOPE / KEV/CH

usage: SLOPE [<min> <max>]

Varies the energy calibration's slope, in keV per channel.

PERT Command: slope

OFFSET / KEV(0)

usage: OFFSET [<min> <max>]

Varies the energy calibration's offset, in keV, e.g. to follow a sample-charging shift.

PERT Command: offset

PIXH [new]

usage: PIXH [<min> <max>]

Varies the PIXE instrumental constant H together with the parameters fitted to the PIXE spectrum. GO varies H of each shell (K, L or M) whose lines of those elements fall in the PIXWIN channels: Fe and Ni K lines in the windows, H_K. The PIXE spectrum then gives only the ratios of the elements, which is all it needs to. The fitted H is written back to the PIXE setup (PIXE H).

Without PIXH, H stays at the PIXE prompt's values, as calibrated on a standard: the PIXE spectrum then gives absolute amounts. PARMS says which H is fitted, and why:

PERT Command: pixh
  varying PIXH
PERT Command: parms
  ...
  PIXE H      K 1   L 1.25   M 1   L fitted (Ta L lines in the PIXE windows)

H scales the counts of every element in its shell, so some element with lines there must not be fitted to PIXE: its amount, from RBS, sets the scale. GO refuses PIXH when every element with lines of a fitted shell in the windows is fitted to PIXE (ATOMS 1 W PIXE and ATOMS 1 Ta PIXE together, say).

Reading the fit report

Your wish? pert get MnPt.pert go
  ...
  Fitting MA8408: Si [5um] - SiO2 [300SIO2] - Ru [40A] - Mn3Pt [300A] - Ru [40A]

  fit took 0.45 s

  reduced chi-square 4.2900 on 792 dof   (was 141.5915)
  66 evaluations, converged
  fwhm                              19.2299  +/- 0.1166   (was 15)
  correction                       0.855636  +/- 0.001678   (was 1)
  kev(0)                            47.3853  +/- 0.1454   (was 48)
  layer 1 thickness                    40 A  +/- 0.3326 A   (was 40 A)   [29 /CM2]
  layer 2 thickness                   314 A  +/- 0.7404 A   (was 300 A)   [242 /CM2]
  layer 3 thickness                    41 A  +/- 0.3266 A   (was 40 A)   [30 /CM2]
  layer 2 composition Mn            2.74154  +/- 0.01577   (was 3)
  kev/ch                            1.59761  +/- 0.0001069   (was 1.59)
  layer 4 thickness                325 SIO2  +/- 6.634 SIO2   (was 300 SIO2)   [215 /CM2]

  MA8408: Si [5um] - SiO2 [325SIO2] - Ru [41A] - Mn2.74Pt [314A] - Ru [40A]
  • Fitting MA8408: … — the sample name and the layer structure before the fit, substrate first. The last line shows the structure after it.
  • reduced chi-square … on … dof — chi-square per degree of freedom, over the error windows; (was …) is the value before the fit. Near 1, the model explains the data as well as counting statistics allow. Much more than 1 means a systematic mismatch: a missing layer, a wrong calibration or geometry, or non-Rutherford scattering in the window. Much less than 1 usually means the window is too narrow.
  • … evaluations, converged — how many simulations the fit ran. did not converge means it stopped at its limit first: check the starting values or narrow the window before trusting the numbers.
  • One line per parameter — the fitted value, its uncertainty, and the starting value. As in SIM SHOW, the other MODE's view follows in brackets. A THICKNESS is in the layer's own unit, with its 10¹⁵ at/cm² (/CM2) in brackets. An ATOMS amount is in /CM2, with the layer's resulting thickness in Å in brackets.
  • data scaled by … — only with a NORMALIZE window: the scale applied, and the CORRECTION it was stored as.