Skip to content

Plotting & display

Plotting & display

The plot is one persistent matplotlib window whose state survives between commands. matplotlib installs by default with pyrump.

OVERLAY

usage: OVERLAY [buffer|file]

Adds another trace to the current plot, without erasing it — on a COMPARE, to its top panel.

Your wish? overlay 0            /* add the simulation on top          */

REPLOT

Redraws the current plot — useful after resizing the window or after a setting that doesn't redraw on its own. Any simulation on it is brought up to date with the sample first, even with LIVE OFF.

LIVE [new]

usage: LIVE [off]

Keeps the simulation on the plot current. After every command that changes the sample (any SIM edit, SIM GET, a PERT fit) or something the simulation depends on (MEV, THETA, FAITHFUL, SCREENING, ...), the simulation curves already on the plot are recomputed and the window redrawn. This covers PLOT 0, OVERLAY 0, the simulation in a COMPARE (with its residuals and chi-square) and each SIM SPLOT element or layer. A SPLOT whose element or layer is no longer in the sample is dropped, with a note. On by default.

  • It never opens a window: with nothing plotted, or the window closed, it does nothing.
  • An XEQ macro counts as one command, so a macro of twenty SIM edits recomputes once, at the end.
  • PERT's GO is not slowed down: the plot is redrawn once, with the fitted sample, after the fit.
  • A sample that can't be simulated (all its layers deleted, say) is reported once, and the plot is left as it was.
  • With PIXE enabled, the PIXE window follows too — it is one switch for both windows, and an open PIXE window follows even with the RBS window closed. PIXE-only settings (detector, FILTER, CALIB, H, ...) redraw the PIXE window themselves, with LIVE on or off, and never touch the RBS plot.

Each redraw costs a fresh simulation (one more for each SPLOT curve, and the PIXE one), so for a slow sample turn it off with LIVE OFF and redraw with REPLOT when you want to see it. LIVE works at any prompt without leaving it. It is a standing preference, like AUTOCMP: put LIVE OFF in ~/.pyrumprc to keep it off; SAVE does not write it.

SIM Command: live off
live off
SIM Command: thick 60 A         /* the plot stays as it is            */
SIM Command: live               /* ...and catches up now              */
live on

FIGSAVE / HCOPY

usage: FIGSAVE <file>

Saves the current plot to an image file (.png by default; format follows the extension). Raster formats such as .png are written at 300 dpi; .pdf and .svg are vector and scale freely. HCOPY is a synonym, the original's own name for the command (a literal hard-copy to a plotter, in RUMP's day).

[new] The RBS plot is saved as <file>_rbs: FIGSAVE fit writes fit_rbs.png. A name that already ends in _rbs isn't doubled. With PAIR ON and the PIXE window open, the PIXE plot is saved next to it as fit_pixe.png (see PIXE).

Your wish? figsave fit
wrote fit_rbs.png

REGION

usage: REGION lo hi

Sets the channel range shown. Any range is accepted, so REGION zooms in and back out. With no plot open, the range is stored and used by the next PLOT. With no arguments it prints the plot settings, the same as PARAMETERS.

Your wish? region 100 400

EXPAND

usage: EXPAND lo hi

Zooms in on part of the current plot and redraws it. The channel numbers are absolute, the same as REGION's, but they must lie inside the range already shown: EXPAND can only narrow the view. Use REGION to widen it again. Limits given high-to-low are swapped. EXPAND needs a plot to be open. If it is rejected, the plot keeps its current range.

REGION does everything EXPAND does and can also zoom out, so it is the one to use in most cases. EXPAND is kept for compatibility with RUMP macros. In the original it was an interactive tool: with no numbers typed, you picked the two limits with the cursor on the plot. pyRUMP has no cursor picking, so the channels must always be typed.

COUNTS

usage: COUNTS lo [hi]

Sets the yield range shown.

LINEAR / SQRT / LOG

Sets the yield axis scale. sqrt redraws immediately with the new scale:

Your wish? sqrt                 /* redraws immediately, sqrt yield    */

On a COMPARE the scale applies to the top panel; the residuals stay linear. LOG ignores a COUNTS floor of 0 or below, which a log axis can't show.

NORMALIZE / RAW

Toggles between normalized and raw yield units on the plot. It applies to COMPARE too, whose residuals and chi-square are then taken on the normalized yield rather than raw counts — the readout says so.

LABELS

usage: LABELS [off]

Turns axis labels on or off.

STRUCTLABEL

usage: STRUCTLABEL [off]

Shows the SIM sample's layer structure (substrate first) as the simulation's legend text, instead of "SIM".

COMPFRAC [new]

usage: COMPFRAC [off]

Shows each layer's composition as atomic fraction (sums to 1) instead of raw stoichiometry, in both STRUCTLABEL and SIM/PERT SHOW. SHOW in MODE ATOMS is the exception: it keeps each element's 10¹⁵ at/cm², with the fractions in brackets.

ENERGY [new]

usage: ENERGY [off]

Puts the x axis in energy (keV) rather than channel, as a single axis along the bottom.

By default (and after ENERGY OFF) the plot uses RUMP's frame: channels along the bottom and energy in MeV along the top, both on the scale of the first buffer plotted. COMPARE shows the energy axis above its upper panel. RUMP itself has no ENERGY command; it always draws both axes.

AXIS

Draws empty axes, with no data.

BLOWUP

usage: BLOWUP <max>

Shorthand for COUNTS 0 <max>.

PARAMETERS / PARMS

Prints the current plot settings.

DISPLAY

usage: DISPLAY [<depth> [<unit>]]

Plots the sample composition against depth, from the SIM description: each element's atomic fraction, layer by layer, in the RBS window. Depth is in 10¹⁵ at/cm², the unit RBS measures.

With no depth, the whole sample is shown, substrate included. A thick substrate then takes up nearly all the axis, so give a depth to see the films: DISPLAY stops there. The depth takes SIM THICKNESS's units, A unless given (nm, um, /CM2). A length is converted layer by layer with each layer's own density, the one its thickness was given with (a compound unit's, such as SIO2, or its elements'), and the plot says what it came to:

Your wish? display 600
  depth 0-600 A = 0-422.2 /CM2 of the sample's 25256.4

RUMP has DISPLAY too, but there it does nothing: its SimDrawSample is an empty stub.